Steel Stud Gauges: Which to Use for Which Walls

Bundles of colour-coded light-gauge steel studs and track stacked on a commercial job site

The right steel stud gauge depends on what the wall has to do, how tall it is and what finish goes on it. For ordinary interior partitions in offices and retail build-outs, non-structural (drywall) studs in the thinner range are common. Taller walls, walls carrying tile or other brittle finishes, and walls that need to resist more movement call for thicker studs, closer spacing or deeper studs. Anything load-bearing or exterior needs structural studs designed by an engineer. Because the same gauge number can describe more than one thickness, manufacturers and specifiers now identify studs by thickness in mils (thousandths of an inch) rather than gauge, and the wall's limiting height from the manufacturer's tables is what actually decides the choice.

Here's how to read the numbers and match studs to walls on a tenant improvement.

Gauge vs mils: why the label matters

Gauge is an old naming system, and it's not precise. The Construction Specifier gives the classic example: 20-gauge interior partition studs are 30 mil thick, while 20-gauge structural studs have a minimum thickness of 33 mil. Same gauge, different product.

That's why ClarkDietrich's product information identifies framing by mils and notes that the minimum delivered thickness is 95% of the design thickness. It also lists the common structural thicknesses with their colour codes, which match the industry colour guide published in STRUCTURE magazine:

Thickness Gauge reference Colour code Typical use
18 mil 25 ga none Non-structural interior partitions
30 mil 20 ga (drywall) Pink Non-structural interior, taller or stiffer partitions
33 mil 20 ga (structural) White Light structural framing
43 mil 18 ga Yellow Structural framing
54 mil 16 ga Green Heavier structural framing
68 mil 14 ga Orange Heavy structural framing

STRUCTURE notes that the pink 30 mil and black 27 mil studs are for interior use only. Manufacturers also sell "equivalent" (EQ) drywall studs, which use thinner, higher-strength steel with stiffening ribs to perform like a conventional stud of a heavier gauge. ClarkDietrich's ProSTUD line, for example, is sold as an equivalent to conventional 25 and 20 gauge drywall framing.

Non-structural vs structural studs

According to The Construction Specifier, non-structural studs are covered by ASTM C645, and their base metal thickness typically ranges from 18 to 30 mil. Studs thicker than 30 mil are generally treated as structural members. Non-structural studs are meant for interior walls that carry no axial load beyond their own weight and finishes.

Structural studs (ASTM C955 for load-bearing members) are used where the wall carries loads from above or resists wind on the building exterior. Those walls should be designed by an engineer, not chosen from a rule of thumb.

What decides the choice for an interior wall

Wall height

The taller the wall, the more it bends under sideways pressure. The Steel Framing Industry Association's technical note on limiting heights explains that interior partitions, while non-structural, still have to resist a uniform lateral load, typically 5 psf. Manufacturers publish limiting height tables showing how tall a wall can be for each stud depth, thickness and spacing. In Canada, CSSBI publishes maximum height tables for interior non-loadbearing partitions.

Deflection limit and finish

How much a wall may bend depends on what's on it. The Steel Stud Manufacturers Association's master specification sets deflection limits for partitions and lists stricter limits (L/240 or L/360) for walls receiving tile, plaster or cut stone. A US Department of Veterans Affairs specification uses L/240 unless noted, and L/360 where a Level 5 drywall finish, tile backing or veneer plaster is shown. Stiffer limits mean shorter allowable heights for the same stud, so tile walls often need a thicker stud, a deeper stud or closer spacing.

For more on why Level 5 finishes are less forgiving of movement and lighting, see the finishing guides at Drywallers.io.

Spacing and bracing

Spacing at 16 inches on centre instead of 24 increases the allowable height. The SSMA specification says that if a partition's height exceeds the manufacturer's limiting height, the installer should add bracing above the ceiling, reduce stud spacing or increase the stud thickness.

Composite vs non-composite tables

SFIA explains that composite tables account for the stiffness the drywall adds, while non-composite tables rely on the stud alone. Using non-composite tables leads to deeper or thicker studs for the same height. Make sure everyone on the job is reading the same table type, with the same board layers.

A practical way to choose

  1. Confirm the wall is non-structural. If it carries load or is part of the exterior envelope, it needs engineered design.
  2. Note the height, finish and any fixture loads. Tile, Level 5, heavy shelving and wall-hung equipment all change the answer.
  3. Pick the deflection limit from the project specification.
  4. Look up the manufacturer's limiting height table for your stud depth, thickness, spacing and board layers.
  5. Adjust depth, thickness or spacing until the wall fits the table, and add backing where fixtures will hang.
  6. Specify by mils, not just gauge, on drawings and purchase orders.

Common mistakes

The bottom line

Choose steel studs by thickness in mils, wall height, deflection limit and finish, using the manufacturer's limiting height tables. Thin non-structural studs suit most painted office partitions; tile, tall walls and heavier loads need more stiffness; and load-bearing or exterior walls belong to an engineer.

Frequently asked questions

What gauge steel stud is used for interior walls?

Ordinary interior partitions commonly use non-structural studs in the 18 to 30 mil range (often called 25 and 20 gauge). The manufacturer's limiting height tables decide what's acceptable for a given wall height and finish.

What's the difference between 20 gauge drywall studs and 20 gauge structural studs?

Twenty-gauge interior partition studs are 30 mil thick, while 20-gauge structural studs have a minimum thickness of 33 mil. That's why studs should be specified by mils.

Do tile walls need heavier steel studs?

Often. Specifications typically apply stricter deflection limits such as L/360 to walls receiving tile, which reduces allowable height, so tile walls may need thicker or deeper studs or closer spacing.

What is a limiting height for steel studs?

It's the maximum height a stud wall can reach for a given stud size, thickness, spacing, lateral load and deflection limit, as published in manufacturer and industry tables.

Sources